Standby generators · installed by licensed, insured local installers we vet
Work out what you need, and what it costs, from your own roof.
Tick what you want running when the power goes. We size the unit against that, then you drop three pins on a satellite picture of your house and we work out the pipe and wire from the distances. Every price includes the automatic transfer switch.
What do you want to keep running?
The common ones are already ticked. Anything with a motor draws two to three times its normal power for a second when it starts, and that spike is what actually decides the size.
Where does it go?
We need the run from the gas meter to the generator, and from the generator to your electrical panel. Put your address in and mark the three spots on the picture.
Sizing uses the natural-gas rating, which is lower than the LP figure on the box — Fort Wayne is a gas town and sizing against LP would sell you a unit that cannot carry what you ticked. Distances are measured on the satellite picture and multiplied by 1.35 because pipe and wire do not run in straight lines, with 10 feet added at each end for rises and terminations. Equipment is priced at the Menards everyday shelf price. The final number is confirmed on site before anything is ordered — a buried obstruction or a panel that needs upgrading is the sort of thing a satellite cannot see.